PLUSH JACKET FR + AT + AE

From: 76,60 Taxes not included

COMPOSITION: 50% Cotton, 39% Modacrylic, 10% Viscose and 1% antistatic fiber
THICKNESS: 260gr / m2

To add a custom logo Click here

 

DESCRIPTION:

  • Multinorm brushed fleece jacket, made of Flame Retardant + Antistatic + Electric arc fabric.
  • High neck made of the same fabric closed by a full flame retardant zipper, from the neck to the hem. Flap of the same fabric covering the entire zipper.
  • Elastic ribbed cuffs.
  • Without side pockets.
  • Straight hemmed hem.

Consult for other colors.


Garment FIRE RESISTANT, ANTISTATIC and ELECTRIC ARC designed to protect the user against brief contact with heat and / or flames, to dissipate the electrostatic charges accumulated in the body and to protect against the thermal risks of an electric arc.

Standard EN ISO 13688/13 (general requirements for Protective Clothing): COMPLIES

Category according to EU Regulation 2016/425 (requirements on the design and manufacture of PPE to guarantee the protection of the health and safety of users): COMPLIES

PERMANENT FIRE-RESISTANT: Standard EN ISO 11612/15 (clothing for protection against heat and flames): A1-A2-B1- C2-F2

EN ISO 11612/15 heat and flames
ISO 17493:2000 Heat resistance to 180º COMPLIES: No ignition, no hole formation
Heat resistance to 260º COMPLIES: No ignition, no hole formation
A) ISO 15025:2002 Flame spread COMPLIES: Without post-combustion; No post-glow, no hole formation, no dripping.
B) ISO 9151:1995 Convective heat COMPLIES:Level B1
C) UNE-EN 366/94 Radiant heat COMPLIES
F) ISO 12127:1996 Contact heat (250º) COMPLIES:Nivel F2
EN ISO 13938-1 Burst resistance COMPLIES

 

PERMANENT ANTISTATICS: Standard EN 1149-5 / 18 (protective clothing with electrostatic properties): COMPLIES

EN 1149-5:2018 ANTISTATIC Value specified by norm Value obtained from the fabric
ELECTRICAL FIELD INTENSITY(S) >0.2 COMPLIES
SEMI-DISSIPATION TIME (t50) <4 seg COMPLIES

 

ELECTRIC ARC: Standard IEC 61482 2: 2018 (protective clothing against the thermal risks of an electric arc): 4 kV – CLASS APC1

Norm IEC 61482-1-2/18 Protective clothing against thermal risks of an electric arc (4 kA)
Test Minimum requirements Values obtained from knitting
Burn time < 5 seg. COMPLIES t<2 sec Class 1
No hole formation No hole formation COMPLIES Class 1
No fusion at the back No fusion at the back COMPLIES Class 1
No drip No drip COMPLIES Class 1
Correct STOLL per sample Correct STOLL per sample COMPLIES Class 1
Operational closure elements Operational closure elements COMPLIES Class 1
Accessories do not contribute negatively to results Accessories do not contribute negatively to results COMPLIES Class 1

Sizing

At Multinormwear we adapt to your size needs with our multinorm garments.
We have a very wide size in our range of products:

  • From the usual sizes that go from the XS to 3XL
  • Range of extra-large sizes, ranging from 4XL to 7XL

DETERMINE YOUR SIZE:

This table will help you determine the size you are looking for.
Measure below the armpits, the most prominent part of your contour (chest, waist or hips).
Keep the tape measure horizontal and, in the table you will find the correspondence in size.

(Tolerance margin of + – 2 cm)

Recommendations

Instructions for use:
This PPE has been conceived to protect the areas of the user’s body covered by it, against heat and flames, favor the dissipation of electrostatic charges from the body and avoid burns caused by an electric arc.
· Ground connection: The person wearing electrostatically dissipative protective clothing must be grounded, either by electrostatically dissipative footwear or by any other suitable means. The resistance between the person and the earth must be less than 108Ω
It should not be removed , or remove in the presence of flammable or explosive atmospheres, or when handling flammable or explosive substances.
For the protection of the whole body, protective clothing should be worn closed and as close to the body as possible, and with other suitable protective equipment. Clothing must be grounded through direct contact with the wearer’s body or through a direct ground connection.
The properties of heat and flame resistance, electrostatic dissipation and protection against thermal risks of an electric arc of this protective clothing can be affected by wear and tear, washing and possible contamination
· The user should not put on any other garment unless it has the same properties of electrostatic dissipation, heat resistance and protection against electric arc as these.
Electrostatic dissipative protective clothing must permanently cover all non-dissipative materials during normal use (including bending and movement)

Recommendations against misuse:
·This PPE should never be used against risks other than those described above.
· Poor maintenance of the garments can modify their performance.
· Dirty laundry can lead to reduced protection.
· The tears must not be repaired by the user.
· Limits of use: This protective clothing must NOT be used in oxygen-rich atmospheres without the prior approval of the technician responsible for safety. This garment does NOT offer protection against electrical stress.

Washing recommendations:

MAX. 25 washes
· Washing at a maximum temperature of 40ºC.
· Bleaching is not allowed.
· The use of softening agents during washing is not allowed.
· Iron at 2 points (max. 150ºC).
· Dry cleaning allowed.
· Tumble drying allowed at low temperatures.

Storage: Store the garment avoiding unnecessary sun exposure and in dry places, protected from any aggressive agent.

The fire-retardant and antistatic properties of this garment are permanent, so the useful life of the PPE will be a direct function of use and care, so it can be used without prior limit as long as no evidence of deterioration is observed. Despite this, its replacement is recommended after a period of one year of use.

Queries