FIREPROOF, ANTISTATIC, ARC, ANTI-ACID AND WELDING PROPERTIES:
This product has been manufactured following the requirements of the EU Regulation 2016/425, for its basic use, according to the standards:
· EN ISO 11612: 2015 Protective clothing against heat and flame.
EN 1149-5: 2018. Protective clothing with electrostaticproperties.
· IEC 61482-1-1: 2019 Protective clothing against the thermal risk of a Electric arc .
· EN 13034: 2005 + A1: 2009 Repellency and penetration of liquids .
· EN ISO 11611: 2015 Protective clothing used during welding and related processes.
PERMANENT FIREPROOF:
Defines the performance of the garments to protect the entire body from heat and flames; defines the requirements for overalls and 2-piece sets thanks to the use of “ad hoc” materials and specific design requirements that guarantee a level of performance to meet the standard, being regulated by different values of heat resistance.
Performance levels according to EN ISO 11612: 2015:
Limited flame spread: A1, A2
There is no destruction to the edges.
There is no hole formation.
There is no merger.
Post-glow time ≤ 2 s.
Post-combustion time ≤ 2 s.
Convective heat: B1 | ||
Performance level |
Intervals HTI24 | |
Min | Max | |
B1 | 4 | <10 |
B2 | 10 | <20 |
B3 | ⋝20 |
Radiant Heat C1 | ||
Performance level | Intervals HTI24 | |
Min | Max | |
C1 | 7 | <20 |
C2 | 20 | <50 |
C3 | 50 | <95 |
C4 | ⋝95 |
Cast iron splash: E3 |
||
Performance level | Cast iron splash (g) | |
Min | Max | |
E1 | 60 | <120 |
E2 | 120 | <200 |
E3 | ⋝200 |
Contact heat: F1 | ||
Performance level | Threshold time (s) |
|
Min | Max | |
F1 | 5 | <10 |
F2 | 10 | <150 |
F3 | ⋝150 |
PERMANENT ANTISTATICS:
Specifies material and construction requirements for electrostatic-dissipating garments used as part of a total grounding system to prevent discharges that can cause fires.
Resistance to the accumulation of electrostatic charges according to EN 1149-5: 2018: S> 0.2 or t50< 4s
- The person wearing electrostatic dissipative protective clothing must be properly grounded. The resistance
between the person and the ground must be less than 108Ω, eg through the use of suitable footwear. - Electrostatic-dissipative protective clothing should not be removed while in the presence of flammable or flammable atmospheres.
explosives or when handling explosive or flammable substances. - The garment must be fully buttoned.
- The use of electrostatic dissipative protective clothing should not be done in oxygen-enriched atmospheres without approval.
prior to the security officer. - The dissipative behavior of electrostatic dissipative protective clothing can be affected by wear, tear,
washes and possible contamination. - Electrostatic-dissipative protective clothing must permanently cover non-compliant materials during use
normal (even in a crouched position and on the move).
ELECTRIC ARC:
This regulation specifies the performance of the garments designed to protect the whole body against the thermal risks of an electric arc due to an accidental and unexpected short circuit in power plants.
IEC 61482-1-1: 2019 Live work. Protective clothing against the thermal risk of an electric arc. Determination of the arc characteristic (ELIM, ATPV and / or EBT)
REPELLENCE AND PENETRATION OF LIQUIDS:
Repellency and penetration of liquids: EN 13034: 2005 + A1: 2009. It defines the performance and minimum safety requirements of the garments studied to guarantee limited protection against liquid chemical agents.
In the event of accidental splashing, during use, of chemicals or flammable liquids on clothing covered by this International Standard, the user must carefully remove the clothing, ensuring that the chemical or liquid does not come into contact with any part. of the skin. The clothing will then be cleaned or removed from service. The partial body protections of type PB [6] have not been subjected to the full suit test.
Repellency and penetration of liquids: EN 13034: 2005 + A1: 2009
Liquids tested | Repellency to liquids | Resistance to liquid penetration |
H2SO4 (30% weight) | 3 of 3 | 3 of 3 |
NaOH (10% weight) | 3 of 3 | 3 of 3 |
1-Butanol | 3 of 3 | 2 of 3 |
Resistance to penetration of liquids in spray form (EN 13034: 2005 + A1: 2009): COMPLIES
WELDING AND RELATED PROCESSES:
EN ISO 11611: 2015 Protective clothing used during welding and related processes.
Establishes minimum safety requirements and test methods for protective clothing (including hoods, aprons, sleeves, and gaiters; hand protection not included) designed to protect the wearer’s body, including the head and feet, and that it must be worn during welding and related processes with comparable risks.
Protective clothing used during welding and related processes according to EN ISO 11611: 2015:
• See Guide to prevention of risks in welding work.
• Garment protects against flames, molten metal splashes, contact heat, convective heat, radiant heat and electrical contact
short-term accidental.
• Additional partial body protection may be necessary, eg for indoor welding.
• The garment is only intended to protect against brief unintentional contact with charged parts of an arc welding circuit and by
Therefore, additional layers of electrical insulation will be required when there is an increased risk of electrical shock.
• Aprons should cover the front of the wearer’s body at least from seam to side seam.
• When additional partial protective garments are used, the basic garment must be at least Class 1.